Valvulator › Echo reference

Aortic root and ascending aorta: normal values

Normal dimensions of the aortic annulus, sinuses of Valsalva, sinotubular junction and proximal ascending aorta.

Open in Valvulator

Sources: Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults (ASE/EACVI), 2015. Last verified 2026-11-08.

Aortic annulus

Source: ASE/EACVI 2015 · Unit: cm

GroupGradeValue
MaleNormal2.0-3.2 cm
FemaleNormal1.9-2.7 cm

Aortic annulus (indexed)

Source: ASE/EACVI 2015 · Unit: cm/m2

GroupGradeValue
MaleNormal1.1-1.5 cm/m2
FemaleNormal1.1-1.5 cm/m2

Sinuses of Valsalva

Source: ASE/EACVI 2015 · Unit: cm

GroupGradeValue
MaleNormal2.8-4.0 cm
FemaleNormal2.4-3.6 cm

Sinuses of Valsalva (indexed)

Source: ASE/EACVI 2015 · Unit: cm/m2

GroupGradeValue
MaleNormal1.3-2.1 cm/m2
FemaleNormal1.4-2.2 cm/m2

Sinotubular junction

Source: ASE/EACVI 2015 · Unit: cm

GroupGradeValue
MaleNormal2.3-3.5 cm
FemaleNormal2.0-3.2 cm

Sinotubular junction (indexed)

Source: ASE/EACVI 2015 · Unit: cm/m2

GroupGradeValue
MaleNormal1.1-1.9 cm/m2
FemaleNormal1.1-1.9 cm/m2

Proximal ascending aorta

Source: ASE/EACVI 2015 · Unit: cm

GroupGradeValue
MaleNormal2.2-3.8 cm
FemaleNormal1.9-3.5 cm

Proximal ascending aorta (indexed)

Source: ASE/EACVI 2015 · Unit: cm/m2

GroupGradeValue
MaleNormal1.1-1.9 cm/m2
FemaleNormal1.0-2.2 cm/m2