Sources: 2025 ESC/EACTS Guidelines for the management of valvular heart disease, 2025; Guidelines for the Evaluation of Prosthetic Valve Function With Cardiovascular Imaging (ASE with SCMR and SCCT), 2024. Last verified 2026-11-08.
Haemodynamic valve deterioration criteria
Source: ESC/EACTS 2025
Grade
Value
Moderate
Mean gradient increase ≥10 mmHg resulting in mean gradient ≥20 mmHg AND EOA decrease ≥0.3 cm2 or ≥25% and/or DVI decrease ≥0.1 or ≥20% vs 1-3 month post-procedure echo; OR new/increased intraprosthetic AR ≥1 grade to ≥moderate
Severe
Mean gradient increase ≥20 mmHg resulting in mean gradient ≥30 mmHg AND EOA decrease ≥0.6 cm2 or ≥50% and/or DVI decrease ≥0.2 or ≥40%; OR new/increased intraprosthetic AR ≥2 grades to ≥moderate-to-severe
Moderate
DVI increase ≥0.4 or ≥20% resulting in DVI ≥2.2, or EOA decrease ≥0.5 cm2 or ≥25% resulting in EOA <1.5 cm2, usually with transmitral gradient increase ≥5 mmHg; OR new/increased intraprosthetic MR ≥1 grade to ≥moderate
Severe
Haemodynamic criteria printed identically to the moderate column; OR new/increased intraprosthetic MR ≥2 grades to ≥moderate-to-severe
Acceleration time
Source: ASE 2024 · Unit: ms
Grade
Value
Normal
<80 ms
Possible_stenosis
80-100 ms
Significant_stenosis
>100 ms
Acceleration time / LV ejection time ratio (AT/ET)
Source: ASE 2024 · Unit: ratio
Grade
Value
Normal
<0.32
Possible_stenosis
0.32-0.37
Significant_stenosis
>0.37
Peak velocity (Vmax)
Source: ASE 2024 · Unit: m/s
Grade
Value
Normal
<3 m/s
Possible_stenosis
3-4 m/s
Significant_stenosis
≥4 m/s
Normal
<1.9 m/s
Possible_stenosis
1.9-2.5 m/s
Significant_stenosis
≥2.5 m/s
Mean gradient (MG)
Source: ASE 2024 · Unit: mmHg
Group
Grade
Value
SAVR
Normal
<20 mmHg
SAVR
Possible_stenosis
20-34 mmHg
SAVR
Significant_stenosis
≥35 mmHg
All
Normal
≤5 mmHg
All
Possible_stenosis
6-10 mmHg
All
Significant_stenosis
>10 mmHg
Doppler velocity index (DVI)
Source: ASE 2024 · Unit: ratio
Group
Grade
Value
SAVR
Normal
>0.35
SAVR
Possible_stenosis
0.25-0.35
SAVR
Significant_stenosis
<0.25
Effective orifice area (EOA)
Source: ASE 2024 · Unit: text
Group
Grade
Value
SAVR
Normal
Reference EOA ± 1 SD
SAVR
Possible_stenosis
1 SD smaller than reference EOA
SAVR
Significant_stenosis
2 SDs smaller than reference EOA
All
Normal
≥2.0 cm2
All
Possible_stenosis
1-2 cm2
All
Significant_stenosis
<1 cm2
Mean gradient, change from baseline (ΔMG)
Source: ASE 2024 · Unit: mmHg
Group
Grade
Value
TAVI
Normal
Change <10 from baseline
TAVI
Possible_stenosis
Increase of 10-19 from baseline
TAVI
Significant_stenosis
Increase ≥20 from baseline
DVI, change from baseline (ΔDVI)
Source: ASE 2024
Group
Grade
Value
TAVI
Normal
Change <0.1 or 20% from baseline
TAVI
Possible_stenosis
Decrease 0.1-0.19 or 20%-39% from baseline
TAVI
Significant_stenosis
Decrease ≥0.2 or ≥40% from baseline
EOA, change from baseline (ΔEOA)
Source: ASE 2024 · Unit: cm2
Group
Grade
Value
TAVI
Normal
Change <0.3 cm2 or 25% from baseline
TAVI
Possible_stenosis
Decrease of 0.3-0.59 cm2 or 25%-49% from baseline
TAVI
Significant_stenosis
Decrease ≥0.6 cm2 or ≥50% from baseline
Jet velocity contour
Source: ASE 2024 · Unit: text
Grade
Value
Normal
Triangular, early peaking
Possible_stenosis
Triangular to intermediate
Significant_stenosis
Rounded, symmetric
Haemodynamic criteria for structural valve deterioration (SVD)
Source: ASE 2024 · Unit: text
Grade
Value
Possible
Increase in mean gradient ≥10 mmHg resulting in a mean gradient ≥20 mmHg with concomitant decrease in EOA ≥0.3 cm2 or ≥25% and/or decrease in DVI ≥0.1 or ≥20% vs baseline (1-3 months post-procedure); OR new/increase of ≥1 grade of intraprosthetic AR resulting in moderate or greater AR
Significant
Increase in mean gradient ≥20 mmHg resulting in a mean gradient ≥30 mmHg with concomitant decrease in EOA ≥0.6 cm2 or ≥50% and/or decrease in DVI ≥0.2 or ≥40% vs baseline; OR new/increase of ≥2 grades of intraprosthetic AR resulting in moderate or greater to severe AR