Valvulator › Echo reference

Tricuspid and pulmonary stenosis: echo severity

Echo findings indicating significant tricuspid stenosis and pulmonary stenosis severity by velocity and gradient.

Open in Valvulator

Sources: Echocardiographic Assessment of Valve Stenosis: EAE/ASE Recommendations for Clinical Practice, 2009. Last verified 2026-11-08.

Mean pressure gradient (MG)

Source: EAE/ASE 2009 · Unit: mmHg

GradeValue
Significant≥5 mmHg

Pressure half-time (T1/2)

Source: EAE/ASE 2009 · Unit: ms

GradeValue
Significant≥190 ms

Inflow time-velocity integral (VTI)

Source: EAE/ASE 2009 · Unit: cm

GradeValue
Significant>60 cm

Valve area by continuity equation

Source: EAE/ASE 2009 · Unit: cm2

GradeValue
Significant≤1 cm2

Peak velocity (Vmax)

Source: EAE/ASE 2009 · Unit: m/s

GradeValue
Mild<3 m/s
Moderate3-4 m/s
Severe>4 m/s

Peak gradient (PG)

Source: EAE/ASE 2009 · Unit: mmHg

GradeValue
Mild<36 mmHg
Moderate36-64 mmHg
Severe>64 mmHg