Valvulator › Echo reference
Tricuspid and pulmonary stenosis: echo severity
Echo findings indicating significant tricuspid stenosis and pulmonary stenosis severity by velocity and gradient.
Open in Valvulator
Sources: Echocardiographic Assessment of Valve Stenosis: EAE/ASE Recommendations for Clinical Practice, 2009. Last verified 2026-11-08.
Mean pressure gradient (MG)
Source: EAE/ASE 2009 · Unit: mmHg
| Grade | Value |
|---|
| Significant | ≥5 mmHg |
Pressure half-time (T1/2)
Source: EAE/ASE 2009 · Unit: ms
| Grade | Value |
|---|
| Significant | ≥190 ms |
Inflow time-velocity integral (VTI)
Source: EAE/ASE 2009 · Unit: cm
| Grade | Value |
|---|
| Significant | >60 cm |
Valve area by continuity equation
Source: EAE/ASE 2009 · Unit: cm2
| Grade | Value |
|---|
| Significant | ≤1 cm2 |
Peak velocity (Vmax)
Source: EAE/ASE 2009 · Unit: m/s
| Grade | Value |
|---|
| Mild | <3 m/s |
| Moderate | 3-4 m/s |
| Severe | >4 m/s |
Peak gradient (PG)
Source: EAE/ASE 2009 · Unit: mmHg
| Grade | Value |
|---|
| Mild | <36 mmHg |
| Moderate | 36-64 mmHg |
| Severe | >64 mmHg |